Schwerpunkt Energie & Umwelt
Permanent URI for this collection
Browse
Browsing Schwerpunkt Energie & Umwelt by Issue Date
Now showing 1 - 20 of 86
Results Per Page
Sort Options
- PublicationEfficient Blue-Light-Emitting Polymer Heterostructure Devices: The Fabrication of Multilayer Structures from Orthogonal Solvents(Wiley, 2010)
;Sax, Stefan ;Rugen-Penkalla, Nicole ;Neuhold, Alfred; ;Zojer, Egbert ;List, Emil J. W.Müllen, KlausAn all-solution processed organic light-emitting diode with enhanced device efficiency based on an additional methanol-soluble polyfluorene layer (see figure) with nonionic ethylene glycol side chains is presented. Due to an asymmetric shift of the energy levels at the polymer/polymer interface, significant efficiency enhancements were obtained.117 1Scopus© Citations 92 - PublicationTheoretische Betrachtungen des elektrischen Lastverhaltens und DSM-Potentials von BürogebäudenDiese Arbeit beschäftigt sich mit dem theoretischen elektrischen Lastverhalten von Bürogebäuden. Da durch den vermehrten Einsatz von fluktuierend erzeugenden, erneuerbaren Energieerzeugungsanlagen die Stromerzeugung nicht mehr einfach dem Bedarf folgen kann, sind variable, zeitkritische Stromtarife zu erwarten. Die Betrachtung der einzelnen Verbraucher erfolgt dabei mithilfe von Zusammen-hängen aus der Literatur. Zudem wurden die Börsenstrompreise des Jahres 2008 sowie die Wetterdaten aus einem Gebäudesimulationstool verwendet. Das Nutzer-verhalten wurde auf Basis von Literaturdaten und einer Wahrscheinlichkeitsmatrix simuliert. Die einzelnen Verbraucher wurden in drei Kategorien eingeteilt. Die Geräte der Infrastruktur sind weitgehend unabhängig von äußeren Einflüssen. Hier ist haupt-sächlich das Nutzerverhalten ausschlaggebend. Bei der Beleuchtung spielt das Wetter durch die Tageslichtversorgung bereits eine bedeutende Rolle, während die äußeren Einflüsse bei der Peripherie (Heizen, Kühlen, Klimatisieren) die Hauptrolle spielen. Durch die Nutzung am Tag, wenn die Strompreise im Allgemeinen höher sind als nachts, beziehen Bürogebäude hauptsächlich zu Zeiten hoher Stromtarife ihre elektrische Leistung. Dies gilt unabhängig von der Gebäudeausstattung und vom Gebäudetyp. Durch die Identifikation und Ausnutzung von Lastverschiebungspotentialen, kann hier jedoch abhängig von der Zusammensetzung der elektrischen Verbraucher ein nennenswerter Prozentsatz des Verbrauchs in Zeiten niedriger Tarife verschoben werden. Die Ausnutzung von Speichern trägt ebenfalls dazu bei, Lastverschiebungspotential zu schaffen. Dabei können verschiedene Arten von Speichern genutzt werden. Elektrochemische Speicher können in Zeiten niedriger Strompreise beladen und deren gespeicherte Energie bei hohen Preisen genutzt werden. Bei Heiz- oder Kühlsystemen, die stark von elektrischen Geräten abhängen, können zudem thermische Speicher zu einer elektrischen Lastverschiebung beitragen. Dabei kann entweder das Gebäude selbst oder eine separate Einrichtung als thermischer Speicher genutzt werden.
357 1329 - PublicationElektrische Energieeffizienz und Lastmanagement als Beitrag zum „Null-Emissions-Gebäude“Efficient use of electricity is an important goal in the ongoing research project "Build2Zero - Integrated concepts for implementation of zero-emission buildings". The project’s task “Electrical energy efficiency" is divided into two subtasks: developing a tool that predicts the annual electricity demand for an office building in the preplanning phase is the first subtask. The focus of this tool is on three priority areas: lighting, auxiliary power (pumps, fans, …) and infrastructure (eg PCs, printers, ...). On the basis of these three priori-ties, the expected annual power requirement is calculated and can be used to support effi-ciency strategies in the preplanning phase. The second subtask was the prediction of electric load behaviour of office buildings during the planning phase. Therefore each electrical application which is typically used in office build-ings, was analysed with regard to its load curve. By aggregation of the individual load curves, different load curves for building systems could be created. Furthermore, the potential for optimization and the necessary conditions for electrical load management in the office build-ing sector were studied in order to supplement the topic of electrical energy efficiency. Based on the presumption of fluctuating electricity tariffs depending on the exchange price at EXAA (2011), energy costs can be reduced noticeably by using active Demand Side Management.
240 342 - PublicationLastverhalten und DSM-Potential in BürogebäudenDieses Paper beschäftigt sich mit dem elektrischen Lastverhalten von Bürogebäuden. Durch den vermehrten Einsatz von fluktuierend produzierenden Anlagen zur erneuerbaren Energieerzeugung kann die Stromerzeugung nicht mehr einfach dem Bedarf folgen. Daher sind zu-künftig variable, zeitkritische Stromtarife zu erwarten. Dies bedeutet, dass der Zeitpunkt der abgerufenen Leistungen kostenrelevant sein wird. Die Betrachtung der einzelnen Verbraucher erfolgte unter Zuhilfenahme von Zusammen-hängen aus der Literatur. Weitere Basisdaten waren die Börsenstrompreise des Jahres 2008, ein fiktiver jährlicher Wetterdatensatz aus einem Gebäudesimulationstool und das Nutzerverhalten anhand einer Wahrscheinlichkeitsmatrix. Die Hauptnutzungszeit der Bürogebäude fällt in jene Zeit, in der die Strompreise bzw. Börsenstrompreise im Allgemeinen höher sind. Durch die Ausnutzung von Lastverschiebungspotentialen kann hier jedoch abhängig von der Zusammensetzung der elektrischen Verbraucher ein nennenswerter Teil des Bezugs in Zeiten niedriger Preise verschoben werden.
238 240 - PublicationBewertung und Optimierung der Energieeffizienz von ThermoprozessanlagenDie vergangenen Jahre standen im Zeichen von stark schwankenden Energiepreisen und Unsicherheiten in der Energieversorgung. Prognosen zeigen eine drastische Differenz zwischen Angebot und Nachfrage an fossilen Energieträgern für die kommenden Jahre. Energieeffizienz ist die Basis, um den zukünftigen weltweiten Energiebedarf decken zu können. Die Sektoren Industrieöfen bzw. Prozesswärme nehmen in Österreich und Deutschland einen merklichen Anteil am Gesamtenergieaufkommen ein. Durch Primärmaßnahmen an den Anlagen und eine konsequente Verwertung von Abwärmeströmen kann es zu einer deutlichen Verbesserung von Anlagenwirkungsgraden in Verbindung mit einer Reduktion von CO²-Emissionen kommen. Am Beispiel einer Durchstoß-Gasaufkohlungsanlage werden interne und externe Energieeffizienzmaßnahmen aufgezeigt und deren Auswirkung auf den Gesamtprozess einer Bewertung unterzogen. Eine Wirkungsgradsteigerung um bis zu 19 % sowie eine Reduktion der CO²-Emissionen um 547 t/a kann erzielt werden. Für die optimale Integration in ein betriebliches Energiekonzept ist die interdisziplinäre Zusammenarbeit von Anlagenhersteller, Energieplaner und Anlagenbetreiber erforderlich.
213 1 - PublicationElectric Load Behaviour and DSM-Potential of Office BuildingsDue to the rising use of fluctuating renewable energy production, electricity production curve in the future will not be able to follow the demand curve anymore. Therefore, time-critical, variable charges are likely to be introduced. Whereas large consumers of electricity already have to pay attention to this issue - the peak demand is measured and cost effective for cus-tomers with a consumption higher than 100,000 kWh or connection power more than 50 kW (ElWOG, 2010) - the topic will become relevant for other customers in the future. Due to the roll-out of Smart Meters, it is very likely that time-relevant tariffs will become standard for all kinds of users, which means that the moment of electricity consumption will be cost-relevant. This paper deals with the electric load behaviour of office buildings and their potential to use Demand Side Management (DSM) to optimise load behavior. Because of use during the day, when prices are usually higher than during the night, office buildings mainly demand electrical energy during periods of high prices. By identification and utilisation of DSM potential, con-siderable sections of the demand can be shifted to hours with lower prices. Another possibil-ity to shift loads is to use thermal or electrochemical storage systems.
473 308 - PublicationImplementing an advanced waste separation step in an MBT plant: assessment of technical, economic and environmental impacts(Sage, 2013-06-23)
; ; ; ; Heavy fractions resulting from mechanical treatment stages of mechanical–biological waste treatment plants are posing very specific demands with regard to further treatment (large portions of inert and high-caloric components). Based on the current Austrian legal situation such a waste stream cannot be landfilled and must be thermally treated. The aim of this research was to evaluate if an inert fraction generated from this waste stream with advanced separation technologies, two sensor-based [near-infrared spectroscopy (NIR), X-ray transmission (XRT)] and two mechanical systems (wet and dry) is able to be disposed of. The performance of the treatment options for separation was evaluated by characterizing the resulting product streams with respect to purity and yield. Complementing the technical evaluation of the processing options, an assessment of the economic and global warming effects of the change in waste stream routing was conducted. The separated inert fraction was evaluated with regard to landfilling. The remaining high-caloric product stream was evaluated with regard to thermal utilization. The results show that, in principal, the selected treatment technologies can be used to separate high-caloric from inert components. Limitations were identified with regard to the product qualities achieved, as well as to the economic expedience of the treatment options. One of the sensor-based sorting systems (X-ray) was able to produce the highest amount of disposeable heavy fraction (44.1%), while having the lowest content of organic (2.0% Cbiogenic per kg waste input) components. None of the high-caloric product streams complied with the requirements for solid recovered fuels as defined in the Austrian Ordinance on Waste Incineration. The economic evaluation illustrates the highest specific treatment costs for the XRT (€23.15 per t), followed by the NIR-based sorting system (€15.67 per t), and the lowest costs for the air separation system (€10.79 per t). Within the ecological evaluation it can be shown that the results depend strongly on the higher heating value of the high caloric light fraction and on the content of Cbiogenic of the heavy fraction. Therefore, the XRT system had the best results for the overall GWP [−14 kg carbon dioxide equivalents (CO2eq) per t of input waste] and the NIR-based the worst (193 kg CO2 eq per t of input waste). It is concluded that three of the treatment options would be suitable under the specific conditions considered here. Of these, sensor-based sorting is preferable owing to its flexibility.177 1Scopus© Citations 2 - PublicationOptimierte Einbindung von Energiespeichern und Photovoltaik unter Berücksichtigung von DSM in BürogebäudenDiese Arbeit beschäftigt sich mit der optimierten Einbindung von Energiespeichern und Photovoltaik in Bürogebäuden unter Berücksichtigung von zeitlich variablen Stromtarifen und Demand Side Management. Durch den vermehrten Einsatz von fluktuierend erzeugenden, erneuerbaren Energieerzeugungsanlagen sind zeitkritische Stromtarife für alle Endverbraucher zu erwarten. Im Zuge dessen wird das Zusammenspiel aus Erzeugungs- und Verbrauchscharakteristik unter Berücksichtigung von Speichern und der Ausnutzung von Lastverschiebungspotentialen für alle Stromkunden relevant. Die Modellierung der einzelnen Erzeugungs- und Verbrauchslastgänge erfolgt dabei mithilfe von Zusammenhängen aus der Literatur sowie diverser Simulationen nach der Bottom Up Methode. Zudem wurden reale Börsenstrompreise eines Jahres sowie reale Wetterdaten verwendet. Das Nutzerverhalten wurde auf Basis von Literaturdaten und einer Wahrscheinlichkeitsmatrix simuliert, jedoch nicht variiert (das Nutzerverhalten war nicht Ziel der Untersuchungen). Die einzelnen Verbraucher wurden in drei Kategorien eingeteilt. Die Geräte der Infrastruktur sind weitgehend unabhängig von äußeren Einflüssen. Hier ist hauptsächlich das Nutzerverhalten ausschlaggebend. Bei der Beleuchtung hat das Wetter durch die Tageslichtversorgung bereits bedeutenden Einfluss, während die äußeren Bedingungen bei der Peripherie (Heizen, Kühlen, Klimatisieren) die Hauptrolle spielen. Durch die Produktion am Tag, wenn die Strompreise im Allgemeinen höher sind als nachts, wird der von der PV-Anlage erzeugte Strom zu günstigen Tageszeiten bereit gestellt. Andererseits beziehen Bürogebäude durch die Nutzung am Tag hauptsächlich zu Zeiten hoher Stromtarife ihre elektrische Leistung. Somit bestehen hinsichtlich der Optimierung des Betriebs von Bürogebäuden verschiedene Möglichkeiten. So kann durch elektrische Lastverschiebung ein erheblicher Teil des nicht durch die PV-Anlage abgedeckten Stromverbrauchs bei Tag in die Nachtstunden verschoben werden, wenn die Strompreise im Allgemeinen niedriger sind als tagsüber. Abbildung 1 zeigt zwei Varianten des Verbraucherlastgangs (Standard, Optimiert) und den Erzeugungsverlauf der PV-Anlage (20 kWp) sowie des Strompreises für einen Wintertag. Abbildung 1: Lastgang Standard; Optimiert inkl. PV; Winterfall Es wurde dazu unter anderem ein Vorheizstrategie verwendet, um den Betrieb elektrisch basierter Wärmeerzeuger (hier Wärmepumpen) in die Nachtstunden zu verlegen. Dies beeinflusst auch den Deckungsgrad der elektrischen Lasten durch die PV tagsüber positiv. Die Lastverschiebung wirkt jedoch nur dann Kostensenkend, wenn Sie auf den Eigenverbrauch des erzeugten PV-Stroms keine negativen Auswirkungen hat. Während bei kleineren PV-Anlagen und im Heizfall (Winter) die aktive elektrische Lastverschiebung kaum Einfluss auf die Eigenverbrauchsquote hat (Verbrauch >> Erzeugung), stellt sich die Situation bei größeren PV-Anlagen im Sommer anders dar. Abbildung 2 zeigt, dass hier bei einer Anlage mit 20 kWp durch die Lastverschiebung unter Ausnutzung einer Vorkühlstrategie bereits überschüssiger PV-Strom vorhanden ist. Abbildung 2: Lastgang Standard; Optimiert inkl. PV; Sommerfall Um hier den Eigenverbrauchsanteil nicht negativ zu beeinflussen, sind zusätzliche Maßnahmen notwendig. So können hier auch tagsüber Verbraucher mit Lastverschiebungspotential bei Überschussstrom aus PV zusätzlich aktiviert werden. Eine weitere Möglichkeit stellt die Einbindung der Wettervorhersage in die Regelung dar. Mit dieser Maßnahme kann anhand der Erzeugungsprognose sowie der Prognose des täglichen Verlaufs des Kühlenergiebedarfs des Gebäudes im Voraus eine Entscheidung über das Ausmaß der Vorkühlung bei niedrigen Strombezugspreisen in der Nacht erfolgen. Auch die Auswirkung auf die Auslegung von Speichern (thermisch bzw. elektrisch) zur Überbrückung der Hochtarifzeiten am Tag kann durch die Einbindung von Lastmanagement bzw. Erzeugungsanlagen gezeigt werden. Nach dem Prinzip von Jahresdauerlinien wurden dazu Stromverbräuche bzw. der Bedarf an thermischer Energie während Zeiten hoher Strompreise (i.d.R. 06:00 – 22:00) täglich aufsummiert und untersucht, wie sich notwendige Speichergrößen durch Optimierungsmaßnahmen verändern. Abbildung 3 zeigt beispielsweise die Auswirkung der Maßnahmen auf die Jahresdauerlinie bei Verwendung eines Stromspeichers. Abbildung 3: Optimierte Speicherauslegung Es konnte insgesamt gezeigt werden, dass die optimierte Einbindung von DSM, Erzeugungsanlagen sowie Speichereinheiten einen nennenswerten Kostensenkungsfaktor in einem Stromnetz mit zeitlich variablen Stromtarifen aufweisen.
509 275 - Publication
520 2 - PublicationIntegrated energy design – Education and training in cross-disciplinary teams implementing energy performance of buildings directive (EPBD)(Elsevier, 2014)
;Brunsgaard, Camilla ;Dvořáková, Pavla ;Wyckmans, Annemie; ;Laskari, Marina ;Almeida, Manuela ;Kabele, Karel ;Magyar, Zoltan ;Bartkiewicz, PiotrOp 't Veld, PeterIn Europe, energy and climate policies started to take shape from the 1990s onwards culminating with the ambitious 20–20–20 climate goals and the Low-Carbon Europe roadmap 2050. The European Commission empower the importance of achieving the objective of the recast Directive on energy performance of buildings (EPBD) that new buildings built from 2021 onwards will have to be nearly zero-energy buildings. The general belief is that the energy performance optimization of buildings requires an integrated design approach and cross-disciplinary teamwork to optimize the building's energy use and quality of indoor environment while satisfying the occupants' needs. In this context, there is a substantial need for professionals such as architects and engineers specifically trained and educated in integrated design approach and trained to work in cross-disciplinary teams. To be able to push forward the development, it is essential that educational institutions foster professionals with such knowledge, skills and competences. An initiative toward this direction is the EU-project of IDES-EDU: “Master and Post-Graduate education and training in multi-disciplinary teams”. The paper describes the necessity of more integrated and cross-disciplinary approaches to building design through state-of-the-art of the building sector and educational initiatives in the participating countries in the project, and through theory of design processes. The paper also communicates the results of newly developed cross-disciplinary education established by fifteen different educational institutions in Europe. Finally, the paper explains and discusses the challenges encountered during development and implementation of the education across different professions and countries.152 1Scopus© Citations 34 - Publication
502 656 - Publication
156 1 - PublicationReed as a Biomass Resource in the Danube Region – An Assessment of Potentials and Different Utilization Possibilities for Energy Production in Austria(Institute for Regional Studies Centre for Economic and Regional Studies Hungarian Academy of Sciences, 2015)
; ;Kitzler, Hannes ;Beckmann, Georg; ;Pfeifer, Christoph199 1 - PublicationDevelopment of a Hardware-in-the-Loop Test Method for Heat Pumps and ChillersThe work presents the development of a Hardware-in-the-Loop test method which enables the solving of integrated energy design problems at a system and concept level for the heat and cold supply of NZEBs based on electrically and thermally driven heat pumps and chillers. The main result is the realization of a test rig consisting of hardware (e.g. thermally driven chiller, or heat pump etc.), of software (e.g. LabView, TRNSYS) and the interface for the interaction of hardware and software.
252 666 - PublicationBewertung und Optimierung der Energieeffizienz von Thermoprozessanlagen(2015)
; ;Buchner, KlausAltena, Herwig189 1 - Publication
184 2 - PublicationEvaluating the Market Competitiveness of Reed Based Biofuels(Institute for Regional Studies Centre for Economic and Regional Studies Hungarian Academy of Sciences, 2015)
; ; 133 2