Abstract: In the present work, the influence of loop forming aspects on the reliability of US-bonded aluminium heavy wires was studied, combining three measurement techniques, for the first time: Laser confocal microscopy based wrinkling characterization, accelerated lifetime measurements BAMFIT and destructive pull tests. The focus of this study was the systematic investigation of the heel region of the wire bond depending on process parameters and especially on the loop geometry regarding durability and lifetime. As first results, effects reducing durability were identified which are not apparent in normal testing and a recommendation for the use of reverse movements can be given.