Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.11790/1396
Title: Complex glass facade modelling for Model Predictive Control of thermal loads: impact of the solar load identification on the state-space model accuracy
Authors: Veynandt, Francois 
Heschl, Christian 
Klanatsky, Peter 
Plank, Helmut 
Issue Date: 26-Nov-2020
Publisher: Leykam
Source: Technologie- und Klimawandel: Energie-Gebäude-Umwelt, 473-481
Project: PVadapt 
Journal: Technologie- und Klimawandel : Energie – Gebäude – Umwelt 
Abstract: Above and beyond improving the efficiency of the building envelope and the energy supply system, the demand-side flexibility in terms of load shifting and peak reduction are vital factors in further increasing the share of volatile renewable energy sources. The thermal activation of building components, like floors and ceilings, enables the cost-effective potential for short-term energy storage to fulfil these requirements. In order to exploit the storage capabilities of active building systems, a reliable model predicted control (MPC) approach is required. However, primarily if a large glass façade element is utilised, the appropriate modelling of solar loads is critical for an effective MPC operation. Hence, based on a dynamic building simulation tool, a characteristic map for the solar load prediction of a glass façade system in combination of external venetian blinds was generated to enhance the state-space model approach for the MPC algorithm. The comparison with a conventional state-space model approach shows the integration of a detailed characteristic map can only marginally improve the prediction accuracy. The additional information required from the glass façade manufacturer and the associated simulation effort is not of substantial value. In contrast, the conventional grey box model enables an entirely datadriven parameter identification, without the manufacturers’ data. Furthermore, the MPC optimisation procedure, searching for the best control strategy, can be more efficient (solver-based optimisation), with shorter computing turnaround times.
Description: Science.Research.Pannonia. 22
URI: http://hdl.handle.net/20.500.11790/1396
ISBN: 978-3-7011-0460-4
Rights: info:eu-repo/semantics/openAccess
Appears in Collections:Energie-Umweltmanagement

Files in This Item:
File Description SizeFormat
9783701104604_473.pdf2.92 MBAdobe PDFView/Open
SFX Query Show full item record

Page view(s)

42
checked on Mar 2, 2021

Download(s) 20

14
checked on Mar 2, 2021

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons