Options
Title
Monitoring dataset from an office room in a real operating building, suitable for state-space energy modelling
Date Issued
2023-07-21
Abstract
To support open science, monitoring data from the living laboratory ENERGETIKUM in Pinkafeld, Austria, is shared here. The dataset provided is especially suitable for data-driven energy modelling of an office room. This can be for model predictive control strategies useful. The dataset provides all necessary variables over a period of sixteen months, with a time step of one minute or fifteen minutes, in MATLAB format (.mat) or in tabs-separated format (.txt). Some variables are raw measurements: ambient (T_Amb) and room (T_Air_Measured) air temperatures, ventilation air flowrate (V_dot_Vent) and supply temperature (T_Vent_In). Other variables are calculated from measurements: heat flows for floor heating (Q_dot_FBH), ceiling cooling (Q_dot_DE) and from internal loads (Q_dot_Int_LO). For the incoming solar irradiance, two façade models using measurements (solar irradiance, movable shading settings) and building characteristics (geometry, glazing and shading optical properties) are used: the simple model (q_dot_Solar_SF) and the enhanced model (Q_dot_Solar_EF). To the background of the façade models, see [1,2].
References:
[1] F. Veynandt, C. Heschl, P. Klanatsky, H. Plank, Complex glass facade modelling for Model Predictive Control of thermal loads: impact of the solar load identification on the state-space model accuracy, Leykam, 2020. http://hdl.handle.net/20.500.11790/1396 (accessed January 31, 2022).
[2] Veynandt, F., Heschl, C., MODELING OF SOLAR RADIATION TRANSMISSION THROUGH TRIPLE GLAZING BASED ONLY ON ON-SITE MEASUREMENTS, in: Verlag der Technischen Universität Graz, Online Conference, 2020. https://doi.org/10.3217/978-3-85125-786-1-03.
References:
[1] F. Veynandt, C. Heschl, P. Klanatsky, H. Plank, Complex glass facade modelling for Model Predictive Control of thermal loads: impact of the solar load identification on the state-space model accuracy, Leykam, 2020. http://hdl.handle.net/20.500.11790/1396 (accessed January 31, 2022).
[2] Veynandt, F., Heschl, C., MODELING OF SOLAR RADIATION TRANSMISSION THROUGH TRIPLE GLAZING BASED ONLY ON ON-SITE MEASUREMENTS, in: Verlag der Technischen Universität Graz, Online Conference, 2020. https://doi.org/10.3217/978-3-85125-786-1-03.
Publication
File(s)
No Thumbnail Available
Name
Measured_data_for_GreyBox_modelling_201808_202001_01min.mat
Size
13.67 MB
Checksum (MD5)
b9ba2c1e45f9d54aa6bbc05fb7d7d635
No Thumbnail Available
Name
Measured_data_for_GreyBox_modelling_201808_202001_15min.mat
Size
1.11 MB
Checksum (MD5)
f8d687444e752d6e085241b4e39d0247
Views
184
Last Month
8
8
Acquisition Date
Nov 23, 2024
Nov 23, 2024
Downloads
154
Last Week
8
8
Last Month
15
15
Acquisition Date
Nov 23, 2024
Nov 23, 2024